THE
KCHF-2-18
SILICON TWO-POSITION-SENSITIVE PHOTODIODE
MAIN
ÑHARACTERISTICS
Operating range of the KCHF,
mmõmm 18õ18
Number of coordinates measured
2
Element spacing,
pcs
.
1
Spectral sensitivity range,
µm
0.4
– 1.05
Current monochromatic responsivity
(λ
= 0.63 µm), A/W, not less
than 0.3
Spacing response non-uniformity
(λ
= 0.63 µm), %,
not over
±5.0
Zero-bias
mode
of
photovoltaic
detector
operation
Dark current at
20
îÑ,
at bias voltage supply,
Ubias
= 10
mV,
nÀ,
not over
10.0
Non-hermetic
construction on a glass-ceramic
substrate, the responsive element
surface being protected with moisture-proof varnish
Weight,
g, not over
4
OPERATING CONDITIONS
Operating temperature range,
îÑ
from minus 45
to
55
Relative air humidity,
%,
at temperature,
îÑ,
up to
80
at
25
RELIABILITY CHARACTERISTICS
Failure rate,
h-1,
not over
5õ10-6
during operating age of
10000
h at confidence coefficient
0.6
Ninety-percent
quality
keeping
period
in
manufacturer’s
packing is
18
months,
as a part of
equipment - not less than
10
years.
FIELD OF APPLICATION
Two-position photoelectric detectors, scientific research.
|